Face Mask, Surgical disposable/ level 1/ bx 50 (MADE IN CANADA)
SKU
WM3669
Availability:In stock
Special PriceCA$39.99CA$49.99
ASTM Level 1
Protection against dust, sand or other air-borne pollutants
3 Ply, form fitting design fluid repelling
Inner protection filter layer
4-Fold design for comfortable fit
Strong polyester elastic ear loops
Disposable, for single use only
Made in Canada
NO Graphene or Biomass Graphene in our masks.
Please contact Wellcare Medical Supplies & Health Care Products Ltd.
Everything from raw materials to the finished product goes through the following five tests, conducted in-house and by third parties:
Bacterial Filtration Efficiency
Particle Filtration Efficiency
Synthetic Blood Penetration
Differential Pressure
Respiratory Resistance
The Bacterial Filtration Efficiency (BFE) test is used to measure a material’s resistance to penetration of bacteria. Our processes uses microbial aerosol liquid spray producing results as percent efficiency and correlating with the ability of the fabric to resist bacterial penetration. This test is performed on filtration materials such as air filters, face masks, surgical gowns and caps that are designed to protect against biological aerosols.
This test is used for FDA and Health Canada submissions and complies with ASTM F2100, ASTM F2101 and EN 14683.
Standards:
ASTM F2100
ASTM F2101
EN 14683
The Particle Filtration Efficiency (PFE) test is used to measure a material’s filtering retention against particles. This test is performed on filtration materials such as air filters and face masks that are designed to protect against particle aerosols.
This test is used for FDA and Health Canada submissions and complies with ASTM F2100 and ASTM F2299.
Standards:
ASTM F2100
ASTM F2299
The Synthetic Blood Penetration or Splash Resistance test is used to measure the resistance of the masks ability to act as a barrier against blood or other liquids. The test uses different levels of synthetic blood volumes directed at high velocity to determine the resistance level.
This test is used for FDA and Health Canada submissions and complies with ASTM F1862, ASTM F2100, EN 14683, ISO 26609, YY 0469 and GB/T 19083.
Standards:
ASTM F1862
ASTM F2100
EN 14683
ISO 26609
YY 0469
GB/T 19083
The Differential Pressure test is used to measure the breathability of masks. Our process is testing through measuring the differential pressure required to draw air through a measured surface area at a constant air flow rate and to test the air exchange pressure of the medical face mask material, which indicates the breathability.
This test is used for FDA and Health Canada submissions and complies with ASTM F2100, EN 149, EN 14683, MIL-M-36954C, GB 19083, GB 2626, GB/T 32610 and YY/T 0969.
Standards:
ASTM F2100
EN 149
EN 14683
MIL-M-36954C
GB 19083
GB 2626
GB/T 32610
YY/T 0969
The respiratory resistance is used for determining the inhalation resistance and exhalation resistance under the regulations of respirators and masks.
This test is in compliance with GB 2626 and GB/T 32610.
Standards:
GB 2626
GB/T 32610
Bacterial Filtration Efficiency
Particle Filtration Efficiency
Synthetic Blood Penetration
Differential Pressure
Respiratory Resistance
Made in Canada
NO Graphene or Biomass Graphene in our masks.
Please contact Wellcare Medical Supplies & Health Care Products Ltd.